Benchtop Turbidity Meter,Economic type
Model:PGZ-20S、1A、200S
Measuring range (NTU):0~20、0~200
Min indication (NTU):0.01, 0.1
Indication error:±8%(±2.5%F.S)
Repeatability:≤0.8%
Zero drift:±0.8%F.S
Benchtop, economical, low-priced, stable work.

Model:PGZ-20S、1A、200S
Measuring range (NTU):0~20、0~200
Min indication (NTU):0.01, 0.1
Indication error:±8%(±2.5%F.S)
Repeatability:≤0.8%
Zero drift:±0.8%F.S
Benchtop, economical, low-priced, stable work.

Model:PGZ-1、200、800
Measuring range (NTU):0~20、0~200、0~800
Min indication (NTU):0.01, 0.1
Indication error:±6%(±2.5%F.S)
Repeatability:≤0.5%
Zero drift:±0.5%F.S
Standard configuration, maintenance free, stable operation, in compliance with ISO international standards.

Model:PGZ-2000、2000A、4000、4000A100
Measuring range (NTU):0~10、0~100、0~1000、0~2000、0~4000
Min indication (NTU):0.001, 0.01
Indication error:±6%(±2%F.S、±3%F.S、±5%F.S)
Repeatability:≤0.5%
Zero drift:±0.5%F.S
Microcomputer, touch keyboard, LCD backlit liquid crystal display.

Model:PGZ-1000
Measurement range NTU:0.00-50.0 50.1-200 200.1-1000(automatic range switchover)
Allowable error of indication:≤±6%
Zero drift:≤±0.3%FS
Stability of indication:≤±1%FS
Repeatability:≤0.5%
7 inch LCD touch screen panel.

Model:PGZ – A Series
Minimum readout NTU:0.01, 0.001
Measuring range NTU:0-20、0-200、0-10、0-100、0-500、0-50、0-1000
Basic error F.S:±6%(±2%F.S)
Repeatability:≤0.5%
Zero drift:±0.5%F.S
Microcomputer, touch keyboard, backlight LCD.

Model: PGA-20B / PGA-1B / PGA-200B
Minimum readout NTU:0.01, 0.1
Measuring range NTU:0-20、0-200
Basic error F.S:±8%(±2.5%F.S)
Repeatability:≤1%
Zero drift:±1%F.S
Small and beautiful appearance, light weight, handheld use, LCD display, LED light source, power off automatically, AC and DC using.

Model:PGA – B Series
Measuring range NTU:0-50、0-500、0-10、0-100、0-1000、0-4000
Minimum readout NTU:0.01, 0.001
Basic error F.S:±6%(±2%F.S)
Repeatability:≤0.5%
Zero drift:±0.5%F.S
The measurement range can be manually selected or automatically switched. The calibration standard value can be set arbitrarily by programming, and the automatic calibration of 1-7 points can be selected quickly and arbitrarily.

Model:PCOD-3M
Measurement range:COD: 5~2000mg/L
Indication error:COD: ≤ ± 5 %
Repeatability:≤3%
Temperature control system:can be set at room temperature ~200 °C, COD digestion temperature is 165 °C

Model:PCOD-810
Measurement range:COD: 5~2000mg/L, measured over dilution
Indication error:COD: ≤ ± 5 %
Repeatability:≤3%
Temperature control system:can be set at room temperature ~180°C, COD digestion temperature is 165 °C

Model:P9011
Measuring range (NTU):0-50 chromaticity (Hazen, pt-co, pcu mg Pt/L)
Min readout (NTU):1 chromaticity
Repeatability:≤3%
Desktop, good stability, maintenance-free.

Model:PF30
Measurement Range:L: 0 to 100
Repeated Accuracy:E<0.05 (take the deviation average after 30 times measuring the whiteboard)
Table Difference:E<0.2
It can be applicable in textile, printing and dyeing, clothing, footwear, leather, chemicals, plastics, film, pigments, paints, inks, metal, photography, toys, etc.

Model:PL-1B、2B、3B
Type:Portable
Testing method:Platinum cobalt standard colorimetric method.
Measuring range:
residual chlorine, total chlorine, Combined residual chlorine:0~5 mg/L
carbon dioxide:0~10mg/L
ozone:0~2 mg/L
Min. readout:0.01mg/L
Error:±5%FS
Repeatability:≤3%

Model:PL-1、2、3
Type:Desktop
Testing method:Platinum cobalt standard colorimetric method.
Measuring range:
residual chlorine, total chlorine, Combined residual chlorine:0~5 mg/L
carbon dioxide:0~10mg/L
ozone:0~2 mg/L
Min. readout:0.01mg/L
Error:±5%FS
Repeatability:≤3%

Model:P9024
Type:Desktop
Testing method:Platinum cobalt standard colorimetric method.
Measuring range:
Ozone:0~2mg/L
Chlorine:0~5mg/L
Total chlorine:0~5mg/L
Carbon dioxide:0~5mg/L
Min. readout:0.01mg/L
Error:±5%FS
Repeatability:≤3%

Model:P9022 / P9025 / P9029
Type:Desktop
Testing method:Platinum cobalt standard colorimetric method.
Measuring range:
Residual chlorine:0~2.5 low range
Residual chlorine:0~10 high range
Total chlorine:0~5.0
Combined residual chlorine:0~2.5
Chlorine dioxide:0~5.0
Nitrite:0~0.3
Dissolved oxygen:0~12
Ammonia nitrogen:0~10
Iron:0~0.8
Min. readout:0.001mg/L
Error:±5%FS
Repeatability≤2%

Model: P9012C
Measuring range (NTU): 0-50,0-500chromaticity (Hazen, pt-co, pcu mg Pt/L)
Minimum indication:0.1 chromaticity
Repeatability:≤1.5%
It can be widely used for platinum cobalt color determination in pure water plants, water plants, domestic sewage treatment plants, beverage plants, environmental protection departments, industrial water, liquor and pharmaceutical industries, epidemic prevention departments, hospitals, chemical products and other departments.